Jump to content

Charlie Knight

Basic Member
  • Posts

    2
  • Joined

  • Last visited

Profile Information

  • Occupation
    Cinematographer
  • Location
    London

Recent Profile Visitors

The recent visitors block is disabled and is not being shown to other users.

  1. Hi All! Just thought id reply to this thread as I recently successfully adapted the 7pin tuchel cable to dtap for vlock power. This thread was super useful but here is what I learned. You cannot use the 12v regulator (as someone above said) it limits the start up power surge and doesn't allow the motor to start moving. I just cut this out and then paired cables together and then it started up! Now onto the cabling.. I paired the red wire (dtap side) to the black wire (tuchel side) and white to white and soldered these together. Worked a treat and is now running off vlock happily! Hope this is of help to some of you. I used this on an MST motor for the Bolex h16 rex5 not the electric ones but I didn't see the need for adapting to XLR, just directly paired the two cables and was running!
×
×